Join the Index

Capability

Data centre cooling systems in Singapore

Systems that remove heat from server halls and hold stable temperature and humidity: chilled-water plant, computer-room air handling (CRAC/CRAH) units, aisle containment, and direct-to-chip or immersion liquid cooling for high-density racks. Buyers select on power usage effectiveness (PUE), rack density and redundancy.

Singapore is now the most cooling-constrained data-centre market in Asia, and cooling engineering — not land or power alone — is the discipline that decides whether a build passes regulatory muster. After a three-year moratorium (2019–2022) on new capacity, the government reopened growth through a pilot Call for Application that awarded roughly 80 MW across four operators, then a Green Data Centre Roadmap (2024) signalling at least 300 MW of additional capacity — but only for facilities that hit aggressive efficiency bars. Data centres already draw about 7% of national electricity, so the binding constraint is thermal: the BCA-IMDA Green Mark for Data Centres and the tropical DC-SG standard push operators toward a design PUE of about 1.3 in Singapore's ambient heat, and NEA's minimum ACMV system-efficiency rules govern the water-cooled chilled-water plants that most large halls still run. The commercial consequence is a scramble for cooling contractors who can certify efficiency, not just move air.

The buyer's stack runs on a small number of decisions. PUE / efficiency is the headline metric operators are graded on. The base architecture is a choice between air-cooled (packaged, higher PUE, simpler) and water-cooled chilled-water plant (lower PUE, dominant at scale), increasingly hybridised with liquid coolingdirect-to-chip cold plates, rear-door heat exchangers, coolant distribution units (CDUs) and full immersion cooling — as AI racks push past 30–100 kW and exceed what air can remove. Inside the hall, precision / close-control cooling (CRAC/CRAH units holding roughly ±1°C) protects mission-critical uptime, and every plant is specified for N+1 or 2N redundancy. On the contractor side the credential that matters for the mechanical build is the BCA ME01 grade, with L6 signalling capacity for the largest unlimited-value projects. The net-new field below splits into precision/CRAC specialists (Citec, Canatec), liquid- and immersion-cooling technology firms with Singapore operations (CoolestDC, Sustainable Metal Cloud) and mission-critical integrators (Power Partners) — sitting alongside the chilled-water M&E contractors already carried in the Construction sector.

Also known as: precision cooling · data center cooling · close-control cooling · CRAC/CRAH · liquid cooling · thermal management

Capability specifications

Air systems
CRAC/CRAH units, hot/cold aisle containment, raised-floor plenum
Water systems
Chilled-water plant, chillers, cooling towers, coolant distribution units (CDU)
Liquid cooling
Direct-to-chip, rear-door heat exchanger, immersion
Efficiency metric
Power usage effectiveness (PUE)
Design guideline
ASHRAE TC 9.9 thermal envelope
Rack density band
~5 kW to 50+ kW per rack (high-density / AI)

Companies with this capability in Singapore

  • DLM Pte Ltd

    Holds unrestricted BCA L6 across ME01 (ACMV), ME05 (Electrical) and ME15 (Integrated Building Services). Builds and maintains M&E for data centres (Tier redundancy, liquid cooling), advanced manufacturing and semiconductors, cleanrooms and pharma labs, with LV/HV maintenance, transformer and HT switchgear testing and AI-driven chiller and energy optimisation.

    Website (opens DLM Pte Ltd in a new tab)
  • Poh Meng Engineering

    Registered at top grade ME15 L6 and ME01 (ACMV) L6, plus ME05 (Electrical) L5. Installs split, VRV, AHU and PAHU units, ductwork and mechanical ventilation, and both air-cooled and water-cooled chilled-water systems with BMS and smart-building controls. Among the top-graded dedicated ACMV houses in the set.

    Website (opens Poh Meng Engineering in a new tab)
  • KION Engineering

    Registered ME01 (ACMV) L5, ME15 L5, ME05 L3 and ME06 L2, and a BCA GB01 Licensed Builder. Designs, installs, tests and commissions central chilled-water, DX and VRV systems with fire protection, plumbing and sanitary, and BMS; projects include Fairmont Singapore.

    Website (opens KION Engineering in a new tab)
  • Cyclect Group

    One of Singapore's most established M&E and MEICA (multi-discipline systems-integration) groups, delivering integrated energy solutions across cooling, solar, cogeneration and heat recovery plus integrated facilities management, and holding the BCA ME05 L6 electrical register grade. Sectors served: data centres, semiconductor, pharma, F&B and chemicals manufacturing, infrastructure (airports, ports, water and waste-to-energy) and marine. HQ at Tuas View Crescent.

    Website (opens Cyclect Group in a new tab)
  • Sentron Engineering (S)

    Registered ME01 (ACMV) L6 and ME15 L5: ACMV installation, ductwork fabrication, duct cleaning and maintenance across residential, commercial and industrial.

    Website (opens Sentron Engineering (S) in a new tab)
  • Fidecs Engineering

    A Singapore M&E contractor whose mechanical scope spans ACMV, chillers, mechanical ventilation, ducting, plumbing and sanitary and fire protection, plus explosion-proof air-conditioning and smoke control; designs to Green Mark. Sectors: defence, healthcare, transport, education, industrial and retail.

    Website (opens Fidecs Engineering in a new tab)
  • Citec International (SEA)

    A critical-power and precision-cooling house for data centres, server rooms and telecom facilities. On power it designs and sizes N+1 UPS systems with load assessment, battery-monitoring, harmonic active filters and heat-load and CFD testing of the power-and-cooling envelope; on cooling it supplies floor-standing, ceiling-mounted (CCMU) and fan-array room units plus in-row and in-rack direct cooling holding temperature within about 1 degree C, with cooling-load calculation, rack-density review and airflow assessment.

    Website (opens Citec International (SEA) in a new tab)
  • Canatec

    A UPS and precision-cooling specialist for mission-critical loads. On power it offers Kohler decentralised parallel architecture (DPA) systems from 10 to 500 kVA with hot-swap modules, up to 96% online and 99% eco-mode efficiency, plus maintenance and consultancy; on cooling it runs three CRAC/CRAH lines (Smart Cooling, Smart In-Row, Smart Nano) plus liquid-cooling infrastructure — CDUs, rear-door heat exchangers, fan-wall units and direct-to-chip components — with CFD analysis and leak and environmental monitoring.

    Website (opens Canatec in a new tab)
  • Power Partners Group

    An Asia-wide mission-critical infrastructure integrator with Singapore operations pairing power protection with advanced cooling: immersion cooling, liquid-cooling systems and thermal management for HPC and data centres, plus modular and prefabricated MEP, an in-house workshop and installation, testing and commissioning.

    Website (opens Power Partners Group in a new tab)
  • CoolestDC

    A Singapore deep-tech liquid-cooling firm using proprietary oblique-fin cold-plate technology: custom cold plates, two-phase cooling, a Liquid-Cooled Compute Pod (LCCP) and integrated liquid-cooled racks with in-house CFD, claiming 25-50% energy savings and PUE below 1.06. Its liquid cooling has been deployed at Digital Realty's SIN11 data centre in Singapore.

    Website (opens CoolestDC in a new tab)
  • KBE Air Conditioning & Engineering

    An ACMV and mechanical-ventilation ductwork specialist installing MV duct systems for car parks, toilets and basements of large commercial and retail buildings.

    Website (opens KBE Air Conditioning & Engineering in a new tab)
  • Sustainable Metal Cloud (SMC)

    A Singapore-headquartered immersion-cooling technology provider (a subsidiary of Firmus Technologies) and NVIDIA partner; its HyperCube system immerses NVIDIA-based servers in synthetic fluid with a claimed roughly 50% electricity reduction versus air.

    Website (opens Sustainable Metal Cloud (SMC) in a new tab)

ENQUIRE

Not sure which supplier?

Tell the Singapore Industry Index what you need — this enquiry is tagged to Data centre cooling systems — and we'll point you to the companies on the record that do it. To reach one company directly, enquire from its profile above.